home *** CD-ROM | disk | FTP | other *** search
/ Netware Super Library / Netware Super Library.iso / nov_info / fyi8 / 08062.dos < prev    next >
Text File  |  1990-08-06  |  2KB  |  37 lines

  1. Number:        E3TH072390U181
  2. Subject:       Memory Above 16MB Not Available on HP 486
  3. Date:          August 2, 1990
  4. OS Version:    386
  5. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 
  6.  
  7. GENERAL 
  8. INFORMATION:   The auto-register memory above 16MB is not working on the 
  9.                Hewlett Packard Vectra 486.  It only sees 16MB when there is 
  10.                actually 32MB installed.  The information for how to see the 
  11.                memory above 16MB was provided by Compaq.  We were informed 
  12.                that it would work on all EISA machines.  It works fine on 
  13.                Compaqs but not on this machine.  Either Hewlett Packard is 
  14.                out of spec or the information provided to us really is not 
  15.                applicable for all EISA machines.
  16.  
  17.                This was not detected during the system test of v3.10 
  18.                because all of the EISA machines that we had with more than 
  19.                16MB were Compaqs and they all worked correctly.
  20.  
  21.                To get around this problem for the time being, you will need 
  22.                to place the following command in your AUTOEXEC.NCF file, 
  23.                right after the server name and IPX address are assigned:
  24.  
  25.                REGISTER MEMORY 1000000 1000000 (This is for a 32MB Machine)
  26.  
  27.                This will allow the extra memory to be available when the 
  28.                volumes are mounted.  We will work with H.P. to find out 
  29.                what they or we will need to change in order to correct 
  30.                this problem.  It is possible that EISA machines from 
  31.                vendors other than Compaq may have this problem too. If so, 
  32.                just use the above work-around.
  33.  
  34.                (X)    This information was verified verbally.
  35.  
  36.                (X)    This information was verified by Engineering.
  37.